5 Modification from Standard Software

5
Modification from Standard Software
Overview
Changed Item
Applicable Drive Models
Maximum Output Frequency
Carrier Frequency
Drive Current Rating
Drive Overload Rating
Control Mode (A1-02)
Frequency Setting Resolution
Frequency reference and output frequency
display units.
<1> <2>
Torque Compensation
On-Delay Compensation
Stall Prevention Level During Acceleration
(L3-02)
Deleted Functions
<1> MEMOBUS/Modbus frequency reference setting resolution is 13bit. E.g. for 1000 Hz reference, 10000 (2710Hex) must be set to 0002Hex MEMOBUS/Modbus
register.
<2> Also applies to register data via MEMOBUS/Modbus communication.
Modified Parameters
Deleted Parameters/Functions from Standard Software
Parameter
A1-06
b1-05
b2-08
b3-06
b3-10
b3-24
b7-xx
b8-xx
b9-xx
C3-05 ~ C3-18
C3-21 ~ C3-24
C4-03 ~ C4-07
C5-xx
C6-01
C6-02
C6-09
d4-11
d4-12
d5-xx
EN 20
High Frequency Software
not available for CIMR-AC4B0515 ~ CIMR-AC4B1200
1000 Hz
Max: 12.5 kHz
Fixed at Heavy Duty (HD) ratings
Fixed at 150%/1 min. (C6-01 not available)
0: V/f
5: OLV for PM
Fixed at 0.1 Hz
Parameter o1-03, b5-20
0: 0.1 Hz
1: 0.01 (Max frequency 100%)
3: User Defined (o1-10 and o1-11)
Enabled only at low speeds.
Enabled only at low speeds. Addition of On-Delay
Compensation Selection parameter S1-01
Maximum setting: 170%
Estimation type Speed Search
High Slip Braking (HSB)
Energy Saving Control
KEB
Motor 2 Selection
Overexcitation Deceleration
Action Selection below Minimum Output Frequency
Magnetic Flux Compensation Value
Output Current 1 during Speed Search (Estimation Type)
Speed Search Detection Compensation Gain (Estimation Type)
Speed Search Method Selection
Automatic Speed Regulation (ASR)
Normal/Heavy Duty Selection
Carrier Frequency during Rotational Auto-Tuning
Bi-Directional Output Selection
YASKAWA ELECTRIC TOEP C710606 48A - AC Drive A1000 1000Hz Software - Quick Start Guide
Name
Application Preset
Droop Control
Energy Saving Control
Zero Servo
Output Voltage Limit
Motor 2 Slip Compensation
Torque Compensation
Carrier Frequency Selection
Stop Position Gain
Torque Control
Standard Software
All
400 Hz
Max: 15 kHz
Depends on C6-01
Depends on C6-01
All
0.01 Hz (less than 100 Hz)
0.1 Hz (above 10 Hz)
Parameter o1-03, b5-20
0: 0.1 Hz
1: 0.01 (Max frequency 100%)
2: RPM
3: User Defined (o1-10 and o1-11)
Enabled throughout the entire frequency
range.
Enabled throughout the entire frequency
range.
Maximum setting: 150%
-