YASKAWA CIMR-AC2B0004 Quick Start Manual page 45

Table of Contents

Advertisement

Model
CIMR-
Terminal
AC
R/L1, S/L2, T/L3
U/T1, V/T2, W/
T3
4B0250
–, +1
<4>
+3
R/L1, S/L2, T/L3
U/T1, V/T2, W/
T3
–, +1
4B0296
<4>
+3
R/L1, S/L2, T/L3
U/T1, V/T2, W/
T3
–, +1
4B0362
<4>
+3
R/L1, S/L2, T/L3
U/T1, V/T2, W/
T3
4B0414
–, +1
<4>
+3
<1> Gauges listed here are for use in Europe and China.
<2> Gauges listed here are for use in the United States.
<3> Gauges listed here are for use in Asia except for China.
<4> Drive models CIMR-AC4B0058 to 4B0414 require the use of closed-loop crimp terminals for UL/cUL compliance. Use only the tools
recommended by the terminal manufacturer for crimping.
Note: Use crimp insulated terminals or insulated tubing for wiring these connections. Wires should have a continuous maximum allowable
temperature of 75°C 600 V UL approved vinyl sheathed insulation. Ambient temperature should not exceed 40°C.
Closed-Loop Crimp Terminal Recommendations
YASKAWA recommends using closed-loop crimp terminals on all drive models. UL approval requires the use of crimp
terminals when wiring the drive main circuit terminals on models CIMR-AC2B0110 to 2B0415 and 4B0058 to 4B0414.
Use only crimping tools as specified by the crimp terminal manufacturer. YASKAWA recommends crimp terminals
made by JST and Tokyo DIP (or equivalent) for the insulation cap.
The table below
matches the wire gauges and terminal screw sizes with YASKAWA - recommended crimp terminals,
tools, and insulation caps. Refer to the appropriate Wire Gauge and Torque Specifications table for the wire gauge and
screw size for your drive model. Place orders with a YASKAWA representatives the YASKAWA sales department.
Wire Gauge
Terminal Screws
2 mm
2
14 AWG
3.5 / 5.5 mm
2
12 / 10 AWG
8 mm
2
8 AWG
YASKAWA ELECTRIC TOEP C710606 48A - AC Drive A1000 1000Hz Software - Quick Start Guide
For Europe and
China
<1>
Recommen
Applicable
ded Gauge
Gauge
mm
mm
2
2
120
95 to 300
120
95 to 300
70 to 300
35 to 300
70
70 to 240
185
95 to 300
185
95 to 300
70 to 300
35 to 300
95
95 to 240
240
95 to 300
240
95 to 300
95 to 300
70 to 300
120
120 to 240
95 × 2P
95 to 150
95 × 2P
95 to 150
70 to 150
70 to 150
95
35 to 95
Crimp Terminal
Model Number
M4
R2-4
M4
R5.5-4
M5
R5.5-5
M4
8-4
M5
R8-5
For U.S.A
<2>
Recommen
Applicable
ded Gauge
Gauge
AWG, kcmil
AWG, kcmil
400
1 to 600
400
1/0 to 600
3/0 to 600
1 to 325
2
2 to 350
500
2/0 to 600
500
2/0 to 600
3/0 to 600
1 to 325
2
2 to 350
4/0 × 2P
3/0 to 600
4/0 × 2P
3/0 to 600
4/0 to 600
3/0 to 600
1
1 to 350
300 × 2P
4/0 to 300
300 × 2P
4/0 to 300
3/0 to 300
3/0 to 300
1
1 to 3/0
Machine No.
YA-4
YA-4
YA-4
YA-4
YA-4
10 UL Standards
For Asia
<3>
Recommen
Applicable
ded Gauge
Gauge
mm
mm
2
2
150
38 to 325
150
38 to 325
200
80 to 325
125
38 to 325
22
22 to 200
200
80 to 325
200
80 to 325
325
80 to 325
150
38 to 325
30
30 to 200
250
80 to 325
250
80 to 325
325
100 to 325
200
80 to 325
30
30 to 200
100 × 2P
80 to 150
125 × 2P
80 to 150
150 × 2P
80 to 150
80 × 2P
80 to 150
38
38 to 100
Tool
Die Jaw
AD-900
AD-900
AD-900
AD-901
AD-901
Tightening
Screw
Torque
Size
N m (lb.in.)
18 to 23
M10
(159 to 204)
32 to 40
M12
(283 to 354)
18 to 23
M10
(159 to 204)
32 to 40
M12
(283 to 354)
32 to 40
M12
(283 to 354)
18 to 23
M10
(159 to 204)
32 to 40
M12
(283 to 354)
32 to 40
M12
(283 to 354)
Insulation Cap
Model No.
TP-003
TP-005
TP-005
TP-008
TP-008
EN 45

Hide quick links: