Modifications From Standard Software - YASKAWA VU*B****AA*-134 Series Manual

V1000 option 1000 hz high frequency custom software

Advertisement

3

Modifications from Standard Software

Changed Item
Applicable Drive Models
Maximum Output Frequency
Carrier Frequency
Drive Current Rating
Drive Overload Rating
Control Mode
DriveWorksEZ (DWEZ)
Communication Option Kits
Frequency Setting Resolution
Frequency reference and
output frequency display
units.
<2> <3>
Torque Compensation
On-Delay Compensation
Stall Prevention Level During
Acceleration (L3-02)
Deleted Functions
<1> In order to set the frequency reference above 1000 Hz, consult the Yaskawa Application Engineering group at
(800-927-5292) for application review and procedures.
<2> MEMOBUS/Modbus frequency reference can be set by 0.1 Hz. For 1000 Hz reference, 10000 (2710Hex) must be
set to 0002Hex MEMOBUS/Modbus register.
<3> Also applies to register data via MEMOBUS/Modbus RTU communication.
YASKAWA ELECTRIC TM.V1000SW.134A 1000 Hz High Frequency Custom Software Supplement
3 Modifications from Standard Software
High Frequency Software
All
1000 Hz (1167)
<1>
Max: 7 kHz
C6-02: 2, B, C, F
Fixed at Heavy Duty (HD) ratings
Fixed at 150%/1 min. (C6-01 fixed)
Fixed at V/f (A1-02 fixed)
No
No
Fixed at 0.1 Hz
o1-03 parameter (same as b5-20)
0: 0.1 Hz
1: 0.01 (Max frequency 100%)
2: Deleted
3: User Defined (o1-10 and o1-11)
Enabled only at low speeds.
Refer to New and Modified Software
Functions on page
14.
Enabled only at low speeds. Addition of On-
Delay Compensation Selection parameter S1-
01
Refer to New and Modified Software
Functions on page
14.
Maximum setting: 170%
• All OLV and OLV for PM specific
parameters
• All OLV and OLV for PM specific monitors
• Estimation type Speed Search
• High Slip Braking (HSB)
• Auto-Tuning
• KEB
• Overexcitation Deceleration
Refer to Modified Parameters on page
Standard Software
All
400 Hz
Max: 15 kHz
C6-02: 1 ~ A, F
Depends on C6-01
Depends on C6-01
V/f, OLV, OLV for PM
Available
Available
0.01 Hz (less than 100 Hz)
0.1 Hz (above 10 Hz)
o1-03 parameter (same as b5-20)
0: 0.1 Hz
1: 0.01 (Max frequency 100%)
2: RPM
3: User Defined (o1-10 and o1-11)
Constant throughout the entire
frequency range.
Enabled throughout the entire
frequency range.
Maximum setting: 150%
10.
-
9