AP7131N>admin(system.snmp.traps)> add
Description:
Adds SNMP trap entries.
Syntax:
add v3
<ip>
Adds an entry to the SNMP v3 access list with the destination IP address set to <ip>, the destination UDP port is set to
<port>, the username set to <user> (1 to 31 characters), and the authentication type set to one of auth, or auth/priv.
The following parameters must be specified if <sec> is not none:
Authentication type <auth> set to
Authentication password <pass1> (8 to 31 chars)
The following parameters must be specified if <sec> is set to auth/priv:
Privacy algorithm set to r
Privacy password <pass2> (8 to 31 chars)
Example:
admin(system.snmp.traps)>add v3 192.168.1.70
symbol123
admin(system.snmp.traps)>list v3 all
Warning: This will display secure information.
Do you want to continue [n/y]?y
index
destination ip
destination port
username
security level
auth algorithm
auth password
privacy algorithm
privacy password
For information on configuring SNMP traps using the applet (GUI), see
<user>
<sec>
sha1
aes
aes
symbol123
<auth>
<pass1>
snmpv3user1
: 1
: 192.168.1.70
: 162
: snmpv3user1
: auth/priv
: sha1
: ********
: aes
: ********
Configuring SNMP RF Trap Thresholds on page
CLI Reference
<priv>
<pass2>
auth/priv
sha1
4-39.
8-197