2-10
Motorola Solutions AP-7131N-FGR Access Point Product Reference Guide
2.7 Mounting an AP-7131N-FGR
An AP-7131N-FGR can attach to a wall, mount under a suspended T-Bar or above a ceiling (plenum
or attic) following the same installation instructions. Choose one of the following mounting options
based on the physical environment of the coverage area. Do not mount the access point in a location
that has not been approved in a site survey.
Refer to the following, depending on how you intend to mount the access point:
•
Wall Mounted Installations
•
Suspended Ceiling T-Bar Installations
•
Above the Ceiling (Plenum) Installations
2.7.1 Wall Mounted Installations
Wall mounting requires hanging the access point along its width (or length) using the pair of slots on
the bottom of the unit and using the access point mounting template for the screws.
CAUTION An access point should be wall mounted to concrete or plaster-wall-
The hardware and tools (customer provided) required to install the access point on a wall consists of:
• Two Phillips pan head self-tapping screws (ANSI Standard) #6-18 X 0.875in. Type A or AB
Self-Tapping screw, or (ANSI Standard Metric) M3.5 X 0.6 X 20mm Type D Self-Tapping
screw
• Two wall anchors
• Wall mount template (included on next page)
• Security cable (optional third part provided accessory)
1. To mount the access point on a wall using the provided template:
board (dry wall) only. Do not wall mount an access point to
combustible surfaces.