2
Adjust the following parameters.
Knob
1
2
3
To set the values to the default values, press [Default].
Making vertical blanking interval adjustment and through mode
settings
Use the following procedure.
1
In the Switcher>Output menu, press [V Blank/Through].
The V Blank/Through menu appears.
The status area shows the output ports and the assigned signals, the vertical
blanking interval for field 1 and field 2, and the through mode Enable/
Disable status.
2
Adjust the parameter.
Knob
2
a) Depending on the signal format, the adjustment range varies as follows.
• 480i: 10 to 19
• 576i: 6 to 22
To return the values to their defaults, press [Default].
3
To enable the through mode, press [Through Mode], setting it to Enable.
Making safe title settings
Use the following procedure.
1
In the Switcher>Output menu, press [Safe Title].
The Safe Title menu appears.
The status area shows the output ports and the assigned signals, with the
box 1, box 2, and cross states.
Parameter
Adjustment
White Clip
Luminance signal white clip value 90.00 to 109.00
Dark Clip
Luminance signal dark clip value
Chroma Clip Chrominance signal clip value
Parameter
Adjustment
Mask End
Final value for vertical blanking
interval
Setting values
−6.85 to +10.00
90.00 to 113.17
Setting values
a)
See note
below
Setup Relating to Switcher Processor