INTERNAL CCs
want the IA Switch controlling a midi-powered amp relay switch to be ON whenever you load your "Lead" preset,
and OFF when you load a "Clean Rhythm" preset. Of course, it is only the initial state that is saved; you may stomp
to change the state of any IA Switch at any time. It is also possible to set IA Switches so their state is GLOBAL, in
which case the saved setting is ignored and the switch's current state will persist across preset changes.
To set or change the saved states of IA Switches for a given preset:
1. Press the EDIT footswitch
2. Press PRESET footswitch to arrive at the PRESET menu and the Select Preset screen:
Preset 000
3. Press and/or hold INCR or DECR footswitches to select the Preset you want to edit.
4. Press PAGE 2x to get to the Preset IA Switch States screen:
IASw 01 OFF
5. Tap and/or hold the INCR or DECR footswitches to select an IA Switch
6. Press PARAMETER to move to ON/OFF field.
7. Tap the INCR or DECR footswitches to toggle the state.
8. Press PARAMETER to return to step 5 to edit additional IA switch states for the selected
preset, or press PAGE 2x to return to step 3 and select a new preset for editing, or press EXIT
to return to PERFORMANCE MODE.
5.2.4 Global General Use Instant Access Switches
General Use Instant Access Switches may optionally be set for Global operation, meaning that their states will be
retained across MFC-101 preset changes. This causes any Saved States (5.2.3) for the IA Switch to be ignored. After
a new preset is loaded, MIDI messages for the current state of each Global IA Switch are re-transmitted. See
section 12.5.11 for how to enable the GLOBAL function of any instant access switch.
IA Switches set up for Axe-Fx Functions (see 12.4.7) will IGNORE being set to Global. Instead, the settings in the
Axe-Fx are used (as usual) to set MFC-101 switch states (and LEDs) when each new preset is loaded.
Fractal Audio Systems MFC-101 Manual