Model FX2N-10PG Pulse Output Block
BFM#18, #17 Target address ΙΙ
7.2.12
The target position (absolute address) or travel distance (relative address) in the 2nd-speed
positioning operation is set.
When the absolute address is used, the positioning operation is done to the target position
specified referring to the current address (BFM#40, #39).
When the relative address is used, the positioning operation is done only by the travel distance
specified from the 1st speed target address.
Here, the user unit (BFM#36) is selected, and the value which also includes the magnification
(BFM#36) of the position data is selected.
BFM#20, #19 Operation speed ΙΙ
7.2.13
The practical operation speed during 2-speed positioning operation and interrupting 2-speed
positioning.
Set the operation speed in the range between the bias speed (BFM#2) and maximum speed
(BFM#1, #0).
(Maximum speed > Operation speed Ι/ΙΙ > Bias speed)
If the operation speed is set at the maximum speed or more, it will operate at the maximum
speed. When the operation speed is set at the bias speed or less, it will operate at the bias
speed.
When operation speed change (BFM#26 b10) is allowed (OFF), the speed during positioning
operation can be changed.
7.2.14

BFM#21 Override setting

By instructing a ration in the override setting, the practical operation speed can be changed
referring to the speed set for the jog speed (BFM#4, #3), operation speed Ι (BFM#16, #15),
operation speed ΙΙ (BFM#20, #19), zero return speed (BFM#6, #5) or creep speed (BFM#7).
The operation speed can be also changed during positioning.
7.2.15

BFM#23, #22 Operation speed current value

When the pulse chain is output, the current value of the operation speed is stored. (When it is
stopped or is in the manual pulse generator input operation, it becomes "0".)
Units are as set in user unit (BFM#36).
Speed
Operation speed
10000Hz
Operation speed
100%
10000Hz
7000Hz
70%
Buffer memory (BFM) 7
Time