Model FX2N-10PG Pulse Output Block
• b1, b0 system unit
Units handled for the position and speed are set.
Item
Motor system
unit
Mechanical
system unit
Compound
system unit
Setting items for position data and speed data are handled in the units shown in the table
below.
Pulse rate (BFM#33, #32)
Feed rate (BFM#35, #34)
Zero point address (BFM#10, #9)
Target address Ι (BFM#14, #13)
Position
Target address ΙΙ (BFM#18, #17)
data
Current address (BFM#25, #24)
Maximum speed (BFM#1, #0)
Bias speed (BFM#2)
Jog speed (BFM#4, #3)
Speed
Zero return speed (high speed) (BFM#6, #5)
data
Zero return speed (creep) (BFM#7)
Operation speed Ι (BFM#16, #15)
Operation speed ΙΙ (BFM#20, #19)
The values above are necessary only when the unit systems for the pulse rate (BFM#33, #32)
and feed rate (BFM#35, #34) are set in "mechanical system unit" and "compound system unit".
When the system is set for "motor system unit", they are ignored.
Bit status
b1
b0
0
0
Controls the position based on "PLS" (pulse).
0
1
Controls the position based on "µm, mdeg, 10
1
0
The compound system units are used as mechanical system for
position command and motor system for speed command.
1
1
Item
Details
Motor system
Mechanical
unit
system unit
•
Pulse
µm
•
•
Invalid
•
mdeg
-4
•
10
µm
•
•
mdeg
•
Pulse
-4
•
10
•
cm/min
•
Hz
•
10deg/min
•
inch/min
Buffer memory (BFM) 7
-4
inch, etc".
Compound
system unit
•
Pulse
µm
•
•
mdeg
-4
inch
•
10
inch
µm
•
•
mdeg
-4
inch
•
10
inch
•
Hz
7-14