Mitsubishi Electric FX2N-10PG User Manual page 84

Pulse output block
Hide thumbs Also See for FX2N-10PG:
Table of Contents

Advertisement

Model FX2N-10PG Pulse Output Block
- Operation information
Refer to the following table.
Setting
value
0
1
2
3
4
- If any m code is used in the after mode during continuous operation, the continuous
operation will be interrupted at the time.
- When a series of continuous operations with m codes are ended and are shifted to the
positioning operation which is registered in the step-advance operation, m code OFF
command must be consistent with START command (START input or BFM#26 b9).
- START signal is necessary to end the step-advance operation and shift to the positioning
operation in which the continuous operation and position-to-speed operation are
registered. (When m code is used, m code OFF command is also necessary.)
- When positioning is shifted from continuous operation to position-to-speed operation or
is on the contrary shifted from position-to-speed operation to continuous operation, it will
be automatically shifted after deceleration and stopping. (When any m code of the after
code is not used and when a m code of the after mode is used, it will wait for m code
OFF command.)
Name
Step-advance
When START signal is turned ON, positioning is executed table by
operation
table. The speed information can be changed during operation.
The next table is continuously and sequentially executed. (Multi-
Continuous
speed operation)
operation
The speed information can be changed during operation.
At the address which is written in the position information, the work
is ac-/decelerated to reach the set speed information. (Position-to-
Position-to-speed
speed operation)
operation
The next table is continuously and sequentially executed.
The speed information can be changed during operation.
END (end)
The table operation is ended.
Positioning operation jumps to the table No. which is set in the
JMP
position information.
Operation pattern 8