Model FX2N-10PG Pulse Output Block
• Jog operation
1) When X004 in the PLC is turned ON, jog operation is executed in the forward direction.
When X005 is turned ON, jog operation is executed in the reverse direction.
(Only when m code is OFF, jog operation can be started.)
- Maximum speed
- Acceleration time
- Deceleration time
- Pulse output format : Forward pulse (FP) / reverse pulse (RP)
- Rotation direction
- Jog speed
Forward jog input
When the reverse operation jog input (X005) is turned ON, the work starts moving in
the reverse direction at the same speed as above.
: 1,000,000Hz
: 100ms
: 100ms
: The current value increases with forward pulse.
: 10,000Hz
10,000 Hz
(X004)
Program example 9
Time
9-11