Model FX2N-10PG Pulse Output Block
6.2.2

A-phase +, A-phase -, B-phase +, B-phase -

The differential line driver or the open collector transistor output type manual pulse generator is
applicable to the terminals φA+, φA-, φB+ and φB-.
External power supply (5V DC) is required for the open collector transistor output.
1) When a differential line driver is used
2) When NPN open collector transistors are used
• For the pin layout, refer to Section 2.3.
Shielded
cable
Manual pulse
A phase
generator
2-phase pulse
Frequency
B phase
30kHz or less
Power supply
Manual pulse
Shielded
generator
cable
A phase
B phase
5V DC
FX
-10PG
2N
Input terminal
φA+
120Ω
φA-
120Ω
φB+
120Ω
φB-
120Ω
FX
-10PG
2N
Input terminal
φA+
120Ω
φA-
120Ω
φB+
120Ω
φB-
120Ω
Wiring 6