Sequence Program - Mitsubishi Electric FX2N-10PG User Manual

Pulse output block
Hide thumbs Also See for FX2N-10PG:
Table of Contents

Advertisement

Model FX2N-10PG Pulse Output Block
9.2.3

Sequence program

Example using the FROM and TO commands
(Initial pulse)
M8002
(RUN monitor)
M8000
(RUN monitor)
M8000
(RUN monitor)
M8000
*1. FX
3U
For the details, refer to the FX
Basic & Applied Instruction Edition.
/FX
Series PLC can use direct specification of buffer memory.
3UC
*1
DTO
K0
K0
K500000
TO
K0
K2
DTO
K0
K3
K10000
DTO
K0
K5
K100000
TO
K0
K7
K1000
TO
K0
K8
DTO
K0
K9
TO
K0
K11
K100
TO
K0
K12
K100
TO
K0
K36
H2000
TO
K0
K27
K4M0
/FX
/FX
/FX
3S
3G
3GC
Maximum speed (500,000Hz)
K1
Bias speed (0Hz)
K0
K1
Jog speed (10,000Hz)
K1
Zero return speed (high speed)
K1
(100,000Hz)
Creep speed (1,000Hz)
K1
Zero point signal number
K1
K1
(1st time)
Zero point address (0)
K0
K1
Acceleration time (100ms)
K1
Deceleration time (100ms)
K1
Parameter
K1
1st-speed positioning
M0
operation
Interrupt 1st-speed positioning
M1
operation
2nd-speed positioning
M2
operation
Interrupt 2nd-speed
M3
positioning operation
Interrupt stop operation
M4
Table operation
M5
Variable-speed operation
M6
Manual pulse generator
M7
input operation
M8
M9
M10
M11
Not defined.
M12
M13
M14
M15
Operation pattern
K1
/FX
Series Programming Manual -
3U
3UC
Program example 9
9-7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec fx series

Table of Contents