1St-Speed Positioning Operation; Outline Of 1St-Speed Positioning Operation; Operation Speed; Address Instruction - Mitsubishi Electric FX2N-10PG User Manual

Pulse output block
Hide thumbs Also See for FX2N-10PG:
Table of Contents

Advertisement

Model FX2N-10PG Pulse Output Block
8.4

1st-speed positioning operation

8.4.1

Outline of 1st-speed positioning operation

START
• Positioning operation
If START is input or START (BFM#26 b9) is turned ON when the 1st-positioning operation
(BFM#27 b0) operation pattern is selected, the positioning operation is started to target
address Ι (BFM#14, #13) at operation speed Ι (BFM#16, #15).
8.4.2

Operation speed

The actual operation speed is expressed as [Actual operation speed = Operation speed Ι
(BFM#16, #15) × Override (BFM#21)].
Operation speed Ι can be changed at all times.
However, the operation speed can not be changed when the speed change disable (BFM#26
b10) during operation is ON.
8.4.3

Address instruction

Absolute address and relative address can be used with BFM#26 b8.
b8=OFF : Absolute address instruction (Travel is set by the distance from
the address value 0.)
b8=ON : Relative address instruction (Travel is set by the distance from
the current address.)
8.4.4

Rotation direction

Absolute address mode : The rotation direction is determined depending on the large/small
Relative address mode : The rotation direction is determined depending on the symbol
Deceleration time
(BFM#11)
Maximum speed
(BFM#1,#0)
Operation speed Ι
(BFM#16,#15)
relationship between the current address (BFM#25, #24) and target
address Ι (BFM#14, #13).
(positive/negative) of target address Ι (BFM#14, #13).
Deceleration speed
(BFM#12)
Target address Ι
(BFM#14,#13)
Bias speed
(BFM#2)
Operation pattern 8
Time
8-12

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec fx series

Table of Contents