Model FX2N-10PG Pulse Output Block
8.10

Variable-speed operation

8.10.1

Outline of variable-speed operation

Operation speed Ι
(BFM#16,#15)
• Positioning operation
When the variable-speed operation (BFM#27 b6) operation pattern is selected, the work is
accelerated to operation speed Ι (BFM#16, #15), and the operation is started.
It is not necessary to turn ON target address Ι (BFM#14, #13) and START (BFM#26 b9).
When operation speed Ι is changed, the acceleration/deceleration is applied according to
the acceleration time (BFM#11) or deceleration time (BFM#12) in order to change to the
speed of operation speed Ι.
(The operation speed can not be changed when the speed change disable (BFM#26 b10)
during operation is ON.)
When operation speed Ι is 0, the work is decelerated and stopped.
The positioning complete flag (BFM#28 b6) is not turned ON.
8.10.2

Operation speed

The actual operation speed is expressed as [Actual operation speed = Operation speed Ι
(BFM#16, #15) × Override (BFM#21)].
When operation speed Ι is 0, the work is decelerated and stopped.
Operation speed Ι can be changed at all times.
However, the operation speed can not be changed when the speed change disable (BFM#26
b10) during operation is ON.
Deceleration time
(BFM#11)
Operation
speed Ι
(BFM#16,#15)
Bias speed
(BFM#2)
600
1400
Deceleration speed
(BFM#12)
Maximum
speed
(BFM#1,#0)
1000
Operation pattern 8
Time
8-28