Model FX2N-10PG Pulse Output Block
9.2.2

Device assignment (PLC)

Element
Input
Auxiliary
relay
Data register
Element No.
X000
Error reset
X001
Stop
X002
Forward limit (The external wiring is the N/C contact.)
X003
Reverse limit (The external wiring is the N/C contact.)
X004
Forward jog
X005
Reverse jog
X006
Zero return operation start
X007
1st-speed positioning operation start
M0
M1
M2
M3
Operation
M4
pattern
M5
M6
M7
M8 to M15
M20
M21
M22
M23
M24
M25
Operation
M26
command
M27
M28
M29
M30
M31
M32 to M35
Target address Ι (Moving distance during 1st-speed positioning
D14,D13
operation: 100,000 pulses)
Operation speed Ι (Operation speed during 1st-speed positioning
D16,D15
operation: 30,000Hz)
D23,D22
Output frequency
D25,D24
Current address (user unit)
D28
Status
D37
Error code
D38
Terminal information
D40,D39
Current address (Pulse-converted value)
Assignment
1st-speed positioning operation (Normal ON)
Interrupt 1st-speed positioning operation (Normal OFF)
2nd-speed positioning operation (Normal OFF)
Interrupt 2nd-speed positioning operation (Normal OFF)
Interrupt stop operation (Normal OFF)
Table operation (Normal OFF)
Variable-speed operation (Normal OFF)
Manual pulse generator input operation (Normal OFF)
Not used. (Normal OFF)
Error reset
Stop
Forward limit
Reverse limit
Forward jog
Reverse jog
Zero return command
Data set type zero return command
Relative address/absolute address
Start
Speed change disablement during operation (Normal enable)
m code OFF command
Not used. (Normal OFF)
Program example 9
9-6