Maintenance Manual > Adjustment > Adjustment Items > SET QUALITY
Model UJF-3042/FX Issued 2010.08.27 Revised 2011.09.30 F/W ver
4.2.13 SET QUALITY
Outline
Setting of the operation mode of user-setting print quality.
SET QUALITY List of Items
No
Item
1
Resolution selection
2
Print quality selection
3
Number of passes selection
4
High-speed scan selection
Work Procedures
FUNCTION
#ADJUST
<ent>
#ADJUST
SET QUALITY
<ent>
#SET QUALITY
X DPI : 300
600
900
1200
#SET QUALITY
QUALITY :NORMAL
FINE
FAST
#SET QUALITY
PASS : 2pass
#SET QUALITY
HIGHSPEED :OFF
ON
© 2011 MIMAKI ENGINEERING CO.,LTD.
300, 600, 900, 1200
NORMAL, FINE, FAST
2, 4, 6, 8, 12, 16, 18, 24, 32
ON/ OFF
1. Select [#ADJUST] -> [SET QUALITY].
2. Select then change the resolution (DPI).
[] / []: Switch
[ENTER]: Confirms (Next)
[END]: Return
3. Select then change the print quality.
[] / []: Switch
[ENTER]: Confirms (Next)
[END]: Return
4. Select then change the number of partition passes.
[] / []: Switch
[ENTER]: Confirms (Next)
[END]: Return
5. Select then change ON/OFF of the High-speed scan.
[] / []: Switch
[ENTER]: Confirms (End)
[END]: Return
1.80 / 1.00
Remark
Description
This can be set if the number of partition passes is
not minimum.
Rev.
2.0
1
2
3
4
5
6
7
8
4.2.13
R.2.0
P.1
Need help?