2011 Mimaki Engineering Co.,Ltd - MIMAKI UJF-3042 Maintenance Manual

Uv printer
Hide thumbs Also See for UJF-3042:
Table of Contents

Advertisement

Maintenance Manual > Disassembly and Reassembly > Driving Parts > Y-axis Motor
Model UJF-3042/FX Issued 2010.08.27 Revised 2011.09.30 F/W ver
6.3.2 Y-axis Motor
Y-axis Motor
 Procedures
To turn power off, be sure to turn the main power OFF.
Loosen (Four screws)
Y-Motor BKT
Press
Two Screws
YM Top BKT
© 2011 MIMAKI ENGINEERING CO.,LTD.
---
Remark
1. Remove the Left Cover .
2. Disconnect the two relay connectors of the motor.
3. Loosen the four screws specified in the figure.
4. Loosen the belt tension.
1) Press the Y Motor BKT in the direction of the arrow until the
belt is well loosened.
2) Tighten the four screws previously loosened.
Tighten securely to prevent the Y Motor BKT from moving
back by spring tension.
5. Remove the YM Top BKT.(Do not remove the bearing.)
Screw : P4x10SMW x2
Rev.
2.0
1
2
3
4
5
6
7
8
6.3.2
R.2.0
P.1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ujf-3042fx

Table of Contents