7.1.4 List of SYSTEM HALT
 List of SYSTEM HALT (6/7)
No.
LCD
Connection check error of FPC cable between
SYSTEM HALT (*)
47
SL-Relay PCB and Slider PCB
11b : SLDR FPC L
SYSTEM HALT (*)
11c : SLDR FPC H
48
FW error
SYSTEM HALT (*)
49
(Serial control F/W error (bit control))
806 : FW/SIO bit
FW error
SYSTEM HALT (*)
50
(Serial control F/W error (WR BUSY))
807 : FW/SIO wbsy
FW error
SYSTEM HALT (*)
51
(Step Motor stop waiting)
808 : FW/STP-MTR
FW error
SYSTEM HALT (*)
52
(XY-axis Motor resolution conversion
809 : FW/XY param
parameter error)
FW error
SYSTEM HALT (*)
53
(Y movable range error)
80a : FW/Y RANGE
FW error
SYSTEM HALT (*)
54
(Motor control task error)
80b : FW/ctrltsk
FW error
SYSTEM HALT (*)
55
(Suction Pump stop waiting time over at
80c : FW/PUMP W
capping)
FW error
SYSTEM HALT (*)
56
(Servo interruption error)
80d : FW/SERVO IT
FW error
SYSTEM HALT (*)
57
(FROM PARAM error (F/W BUG))
80e : FW/FROM prm
FW error
SYSTEM HALT (*)
58
(Virtual serial CH setting error)
80f : FW/SIO vch
FW error
SYSTEM HALT (*)
59
(No keyboard RDI)
810 : FW/KEY RDI
FW error
SYSTEM HALT (*)
60
(Serial control F/W error (RD BUSY))
811 : FW/SIO read
FW error
SYSTEM HALT (*)
61
(Cartridge number error)
812 : FW/CRTRG NO
© 2013 MIMAKI ENGINEERING CO.,LTD.
1.80 / 1.00
Cause
1. Check whether FPC cable connection connector of the
Slider PCB (CN2, 4, 6) and the SL-Relay PCB (CN3, 7, 8)
is proper.
2. Disconnect and connect the FFC and Twist pair Cable
located between the Slider PCB and the SL-Relay
PCB.
3. Disconnect and connect the FFC and Twist pair Cable
located between the Main PCB and the SL-Relay PCB.
4. Replace the FFC(or Twist pair Cable) located
between the Slider PCB and the SL-Relay PCB.
5. Replace the FFC(or Twist pair Cable) located between
the Main PCB and the SL-Relay PCB.
6. Replace the Slider PCB with a new one.
6.4.5)
7. Replace the SL-Relay PCB with a new one.
(Refer to 3.3.2)
8. Replace the Main PCB with a new one.
1. Update F/W.
2. Check and clear the parameter.
3. Disconnect and connect the FFC located between the
Main PCB and the SL-Relay PCB.
4. Disconnect and connect the FFC located between the
Main PCB and the Station III PCB.
5. Disconnect and connect the FFC located between the
SL-Relay PCB and the Slider PCB.
6. Replace the FFC located between the Main PCB and
the SL-Relay PCB.
7. Replace the FFC located between the Main PCB and
the Station III PCB.
8. Replace the FFC located between the SL-Relay PCB
and the Slider PCB.
9. Replace the Main PCB with a new one.
Remark