Maintenance Manual > Workflow > UV UNIT > Replacement of LEDUVx2-DRIVE PCB Assy
Model UJF-3042/FX Issued 2010.08.27 Revised 2011.09.30 F/W ver
3.5.2 Replacement of LEDUVx2-DRIVE PCB Assy
 List of Replacement Procedures
Item
Cooling Water
1.
Drain the cooling water
Power OFF
Main power OFF
2.
Covers
Removal of the covers
3.
LED-UV UNIT 4.
Removal and disassembling of the
LED-UV UNIT
Exchange the PCB
5.
Assembling of the LED-UV UNIT
6.
and attaching it
Covers
Mounting of the covers
7.
Cooling Water
Filling cooling water
8.
Power ON
Main power ON
9.
Operation
Operation checking of the LED- UV
10.
check
UNIT
 Be sure to wear Protective Glasses and Working Gloves during the work operation.
© 2011 MIMAKI ENGINEERING CO.,LTD.
Work operation
Drain the cooling water of the LED-UV Unit
"#ADJUST EXCHANGE LED UV"
Remove the Front Cover, Upper Cover.
Remove the LED-UV UNIT and disassemble it until PCB can be
replaced.
Perform the procedures up to the Step 11. of "6.7.1 LED-UV
UNIT"
Exchange the LEDUVx2-DRIVE PCB Assy.
Assemble the LED-UV UNIT and attach it.
Mount the covers which have been removed.
Fill cooling water of the LED-UV UNIT "Total amount: 450ml".
Check the operation of the LED - UV UNIT
1.80 / 1.00
Remark
LEDUVx2-DRIVE PCB Assy
Description
Rev.
2.0
1
2
Ref.
4.2.8
3
-
6.1.1
6.7.1
4
5
6.1.1
-
-
-
6
7
8
3.5.2
R.2.0
P.1

Hide quick links: