7.1.2 List of Error Messages
 List of Error Messages (2/9)
No.
LCD
ERROR 146
9
E-LOG SEQ
ERROR 151
10
Main PCB V1R2
ERROR 152
11
Main PCB V2R5
ERROR 153
12
Main PCB V3R3
ERROR 154
13
Main PCB V05
ERROR 155
14
Main PCB V35-1
ERROR 156
15
Main PCB V5B
ERROR 157
16
Main PCB VTT
ERROR 158
17
Main PCB V352
ERROR 16e
18
Main PCB V3R3B
ERROR 15f
HEAD DRIVE HOT
19
ERROR 171
NEW HEAD CONNECT
20
ERROR 172
21
Main PCB Q6 Check
ERROR 201
22
COMMAND
ERROR 202
PARAMETER
23
ERROR 203
Ment Command
24
© 2013 MIMAKI ENGINEERING CO.,LTD.
Cause
Sequential number abnormality of the
event log
Main board 1.2V power supply is
abnormal.
Main board 2.5V power supply is
abnormal.
Main board 3.3V power supply is
abnormal.
Main board 5V power supply is abnormal.
Main board 35-1V power supply is
abnormal.
Main board 5VB power supply is
abnormal.
Main board VTT power supply is
abnormal.
Main board 35-2V power supply is
abnormal.
Main board 3.3VÇa power supply is
abnormal.
COM driver becomes the high
temperature.
New Print Head was recognized.
The main PCB Q6 is disabled (short mode).
(Displayed only at startup in the maintenance
open mode or other than SUPPORT=0.)
Command error
Other data than commands is received
Parameter error
Parameter out of the numeral value range
is received
Maintenance command
Operation of a maintenance command fails
* Non-disclosed command
Parameter Up/Download and time
setting (LcAeMent [M0xfe])
1.80 / 1.00
Remark
List of Countermeasures
1. Initialize a Event log.
2. Replace the Main PCB with a new one.
1. Replace the Main PCB with a new one.
1. Replace the Main PCB with a new one.
1. The output voltage check of the Power supply PCB.
2. Replace the Power supply PCB with a new one.
to 6.4.1)
3. Replace the Main PCB with a new one.
1. Replace the Main PCB with a new one.
1. Replace the Main PCB with a new one.
1. Replace the Main PCB with a new one.
1. Confirm movement of Slider Relay Cooling Fan.
2. Disconnect and connect the FFC located between the
Slider PCB and the SL-Relay PCB.
3. Replace the SL-Relay PCB with a new one.
(Refer to 3.3.2)
4. Replace the FFC located between the Slider PCB and
the SL-Relay PCB
5. Replace the Print Head with a new
6. Replace the Slider PCB with a new one.
(Refer to 6.4.5)
It is normal that an error occurs only at the time of the first
start after having connected a new head.
It is abnormal that an error occurs at the time of start every
time..
1. Check connection between the Slider PCB from the
Print Head
2. Replace the Slider PCB with a new one.
(Refer to 6.4.5)
3. Replace the Print Head with a new
3.1.1)
1. Replace the Main PCB with a new one.
1. Check if the output set of the PC matches the set of the
machine side?
2. Change the profile.
3. Check if there is no parameter error?
4. Check if there is no trouble on the USB Cable?
5. Replace the USB Cable.
6. Replace the Main PCB with a new one.
1. Check the PRM file.
2. Check the number of each parameter.
(if PRM matches up to the machine.)
Rev.
2.0
(Refer to 3.3.1)
(Refer to 3.3.1)
1
(Refer to 3.3.1)
(Refer
(Refer to 3.3.1)
2
(Refer to 3.3.1)
3
(Refer to 3.3.1)
(Refer to 3.3.1)
4
one.
(Refer to 3.1.1)
5
6
one.
(Refer to
(Refer to 3.3.1)
7
8
(Refer to 3.3.1)