Maintenance Manual > Disassembly and Reassembly > UV Parts > LED UV UNIT
Model UJF-3042/FX Issued 2010.08.27 Revised 2011.09.30 F/W ver
6.7.1 LED UV UNIT
Reflector BKT
Glass
Holder
Glass cushion x4
LED UV Irradiation Assy
© 2011 MIMAKI ENGINEERING CO.,LTD.
12. Remove the Reflector BKT.
• Fixing screw x2
13. Remove the Glass Holder and the Glass.
• Fixing screw x2
Glass
14. Take the Glass cushions out.
 Be careful not to lose it.
This is the end of disassembling.
 It is strictly prohibited to perform maintenance by
disassembling more from the status indicated in
the left figure.
15. Reverse the disassembly procedure for reassembly.
---
Remark
The Assy in the left figure is assembled in the
factory. Therefore, to disassemble, assemble and
use parts again in the field may cause problem of
heat release defect etc.