Maintenance Manual > Disassembly and Reassembly > Driving Parts > X-axis Motor Assy
Model UJF-3042/FX Issued 2010.08.27 Revised 2011.09.30 F/W ver
6.3.1 X-axis Motor Assy
X-axis Motor Assy
To turn power off, be sure to turn the main power OFF.
 Procedures
fixing screws of the coupling
cap screw x4
© 2011 MIMAKI ENGINEERING CO.,LTD.
---
Remark
1. Move the Y-Bar to the farthest position.
2. Raise the Table to the highest position and then remove it.
Refer to
"6.3.3
Table" for removing method.
3. Remove the Key Panel Assy.
Refer to "
6.1.2 Key Panel Assy
4. Loosen the two fixing screws of the coupling of the worm gear
side.
 Screws of X motor side is fixed with the Screw
adhesive , it cannot be removed.
5. Remove the four cap screws that fix the X Motor BKT.
" for removing method.