Maintenance Manual > Workflow > Electrical Parts > Replacement of Main PCB
Model UJF-3042/FX Issued 2010.08.27 Revised 2011.09.30 F/W ver
3.3.1 Replacement of Main PCB
Outline
If Main PCB Assy. has replaced, various parameters must be registered to Main PCB ROM after the replacement.
Considerable time is required to readjust and reconfigure these settings. Therefore, for ease of use and better printing
quality, copy (upload) the setting value to a PC before replacement, and write (download) the copied settings onto the
Main PCB from the PC after replacement.
If it is impossible to upload the parameters, conduct Parameter Draw to note the setting values.
Then manually register the values after replacing the PCB.
List of Replacement Procedures
Item
Advance prepa-
Parameter upload
1.
ration
Power OFF
Main power OFF
2.
Covers
Removal of covers.
3.
Main PCB
Removal of the Main PCB Assy.
4.
Assy.
Mounting of the Main PCB Assy.
5.
Power ON
Main power ON
6.
Check
Updating the firmware
7.
Parameter initialization
8.
Parameter download
9.
Covers
Mounting of the covers
10.
© 2011 MIMAKI ENGINEERING CO.,LTD.
Work operation
Before the PCB is replaced, upload its parameter to the PC.
Pull the Power Supply Chassis from the back.
Remove the Main PCB Assy..
Mount the Main PCB Assy..
Upgrade the firmware to the latest version.
Start up the machine in maintenance mode and initialize the param-
eters.
Download the parameter which has been uploaded in the operation
"1".
Put the Power Supply Chassis in the original place.
1.80 / 1.00
Remark
Description
* See "SERVICE DOCUMENTS".
Rev.
2.0
1
2
Main PCB Assy.
3
4
Ref.
5
1
*
–
6.1.1
6
6.4.2
–
1
*
7
1
*
6.1.1
8
3.3.1
R.2.0
P.1
Need help?