Table 8 Storage Management Provider errors (continued)
Error code
Error message
0x25005068
The virtual disk could not complete the operation
because its health or operational status does not
permit it.
0x24005069
Enclosure not found in cache.
0x2500506A
Failed to update enclosure in cache.
0x2400506B
Failed to get the enclosure for the physical disk.
0x2400506C
Failed to get WMI class names to subscribe.
0x2100506D
SMP assembly file not found.
0x2700506E
The registry key
HKLM\HARDWARE\Description\System\BIOS
was not found.
0x2700506F
The registry key
HKLM\HARDWARE\Description\System\BIOS\
SystemProductName
was not found.
0x21005070
SmartArray.dll file not found.
0x21005071
Raptor.dll file not found.
0x21005072
Failed to get the library name to load.
0x25005073
Failed to release the lock.
0x24005074
Failed to create the mutex.
0x24005075
Failed to get the proxy to the controller library.
0x25005076
The resiliency setting does not match the pool's
resiliency setting.
0x25005077
The operation was successful but the storage
provider cache is out of date. You must update
the storage provider cache before proceeding
further.
0x25005078
The specified friendly name already exists.
0x20005079
The Storage Pool could not complete the
operation because its health or operational status
does not permit it.
0x2500507A
One of the physical disks specified is assigned to
other storage pool.
0x2300507B
This operation is supported only for spare drives.
0x2000507C
The physical drive could not complete the
operation because its health or operational status
does not permit it.
164 Troubleshooting, servicing, and maintenance
Recommended action
Update the storage management provider cache by
invoking Windows PowerShell command
Update-StorageProviderCache.
Restart Storage Management Service.
Update the storage management provider cache by
invoking Windows PowerShell command
Update-StorageProviderCache.
Restart Storage Management Service.
Restart Storage Management Service.
Re-install Storage Management Provider.
The system is in an invalid state. Contact HPE Support.
The system is in an invalid state. Contact HPE Support.
Re-install Storage Management Provider.
Re-install Storage Management Provider.
Re-install Storage Management Provider.
Update the storage management provider cache by
invoking Windows PowerShell command
Update-StorageProviderCache.
Restart Storage Management Service.
Restart Storage Management Service.
Update the storage management provider cache by
invoking Windows PowerShell command
Update-StorageProviderCache.
Update the storage management provider cache by
invoking Windows PowerShell command
Update-StorageProviderCache.
Update the storage management provider cache by
invoking Windows PowerShell command
Update-StorageProviderCache.
Check the health and operational status of the physical
drives. Please retry the operation.
Update the storage management provider cache by
invoking Windows PowerShell command
Update-StorageProviderCache.
Retry the operation.
Check the health and operational status of the physical
drives. Please retry the operation.