Storage Utilization Graph
Use the <StorageUtilizationGraph> sub-element to define the threshold value for the
labels in the storage utilization graph on the Overview tab. The value is entered in percentage.
<NoDataLabelThreshold percentage> specifies the value in percentage that indicates
if the labels are displayed in the graph. For example, if the threshold value is 5% but the
free space available in the system is 3%, then 3% is not displayed because it is less than
the threshold value. The default value is 5% but you can change it to any value between
1% to 100%.
Storage
The <Storage> sub-element defines the properties for the drives, volumes, and shares on the
Storage tab.
<UpdateCache> specifies the time for the storage provider cache update. The storage
provider cache is updated with the latest storage configuration. By default, the cache is
updated every 360 minutes. The minimum time that you can specify for cache update is 360
minutes.
<Discovery> specifies the discovery time based on which the storage data is discovered
and updated. By default, the storage data is discovered every 15 minutes. The minimum
time that you can specify for storage data discovery is 15 minutes.
System Tabs
The <SystemTabs> sub-element updates the data on the Hardware and Software tabs.
<Discovery> specifies the discovery time based on which the hardware health status is
updated. The default value is 24 hours. The minimum value must be 30 minutes.
Event Logs
The <EventLogs> sub-element updates the data on the Critical, Warning, and Informational
tabs.
<Discovery> specifies the discovery time based on which the data is updated on the
Critical, Warning, and Information tabs. The default value and minimum value is 5 minutes.
Network
The <Network> sub-element defines the properties of the network interfaces, teams, and VLANs.
<NetworkTabOverview> specifies the discovery time based on which the bandwidth of
the interfaces is discovered and updated. By default, the bandwidth of the interfaces is
discovered every minute. The minimum time that you can specify for the bandwidth of the
interfaces is one minute.
<NetworkInterfaceTeamVLAN> specifies the discovery time based on which the interface,
team, and VLAN details are discovered and updated. By default, the interface, team, and
VLAN details are discovered every 15 minutes. The minimum time that you can specify for
this discovery is 15 minutes.
IMPORTANT:
If you enter a value that is lower than the minimum required value in the
dashboard configuration file, the StoreEasy Dashboard discards the new value and considers
the default value to update and display the data.