Displaying And Maintaining Rmon Settings - HP 5920 Configuration Manual

Table of Contents

Advertisement

Entry
Alarm
Private alarm
To configure the RMON alarm function:
Step
1.
Enter system view.
2.
(Optional.) Create an
event entry in the event
table.
3.
Create an entry in the
alarm table or private
alarm table.

Displaying and maintaining RMON settings

Execute display commands in any view.
Task
Display RMON statistics.
Display RMON history control
entries and history samples.
Display RMON alarm entries.
Parameters to be compared
Alarm variable (alarm-variable)
Sampling interval (sampling-interval)
Sample type (absolute or delta)
Rising threshold (threshold-value1)
Falling threshold (threshold-value2)
Alarm variable formula (prialarm-formula)
Sampling interval (sampling-interval)
Sample type (absolute or delta)
Rising threshold (threshold-value1)
Falling threshold (threshold-value2)
Command
system-view
rmon event entry-number [ description string ] { log |
log-trap security-string | none | trap security-string }
[ owner text ]
Create an entry in the alarm table:
rmon alarm entry-number alarm-variable
sampling-interval { absolute | delta }
[ startup-alarm { falling | rising | rising-falling } ]
rising-threshold threshold-value1 event-entry1
falling-threshold threshold-value2 event-entry2
[ owner text ]
Create an entry in the private alarm table:
rmon prialarm entry-number prialarm-formula
prialarm-des sampling-interval { absolute | delta }
[ startup-alarm { falling | rising | rising-falling } ]
rising-threshold threshold-value1 event-entry1
falling-threshold threshold-value2 event-entry2
entrytype { forever | cycle cycle-period } [ owner
text ]
Command
display rmon statistics [ interface-type interface-number]
display rmon history [ interface-type interface-number ]
display rmon alarm [ entry-number ]
113
Maximum number
of entries
60
50
Remarks
N/A
By default, the RMON
event table does not
contain entries.
By default, the RMON
alarm table and the
private alarm table do
not contain entries.
You can associate an
alarm with an event
that has not been
created yet. The alarm
will trigger the event
only after the event is
created.