Step
3.
Create an entry in the
alarm table or private
alarm table.
Table 7 RMON configuration restrictions
Entry
Event
Alarm
Prialarm

Displaying and maintaining RMON

Task
Display RMON statistics.
Display the RMON history
control entry and history
sampling information.
Display RMON alarm
configuration.
Display RMON private alarm
configuration.
Display RMON event
configuration.
Display log information for
event entries.
Command
Create an entry in the alarm table:
rmon alarm entry-number alarm-variable
sampling-interval { absolute | delta }
rising-threshold threshold-value1 event-entry1
falling-threshold threshold-value2 event-entry2
[ owner text ]
Create an entry in the private alarm table:
rmon prialarm entry-number prialarm-formula
prialarm-des sampling-interval { absolute |
changeratio | delta } rising-threshold
threshold-value1 event-entry1 falling-threshold
threshold-value2 event-entry2 entrytype { forever |
cycle cycle-period } [ owner text ]
Parameters to be compared
Event description (description string), event type (log, trap,
logtrap or none) and community name (trap-community or
log-trapcommunity)
Alarm variable (alarm-variable), sampling interval
(sampling-interval), sampling type (absolute or delta), rising
threshold (threshold-value1) and falling threshold
(threshold-value2)
Alarm variable formula (alarm-variable), sampling interval
(sampling-interval), sampling type (absolute, changeratio or
delta), rising threshold (threshold-value1) and falling
threshold (threshold-value2)
Command
display rmon statistics [ interface-type
interface-number ] [ | { begin | exclude |
include } regular-expression ]
display rmon history [ interface-type
interface-number ] [ | { begin | exclude |
include } regular-expression ]
display rmon alarm [ entry-number ] [ | { begin |
exclude | include } regular-expression ]
display rmon prialarm [ entry-number ] [ |
{ begin | exclude | include } regular-expression ]
display rmon event [ entry-number ] [ | { begin |
exclude | include } regular-expression ]
display rmon eventlog [ entry-number ] [ | { begin
| exclude | include } regular-expression ]
70
Remarks
Use at least one
command.
Maximum number of
entries
60
60
50
Remarks
Available in any view
Available in any view
Available in any view
Available in any view
Available in any view
Available in any view