Configuring The Monitor Port For A Local Mirroring Group - HP 5920 Configuration Manual

Table of Contents

Advertisement

Step
2.
Enter interface view.
3.
Configure the port as a source
port for the specified local
mirroring group.

Configuring the monitor port for a local mirroring group

On the source device, configure the tunnel interface as the monitor port. On the destination device,
configure the port that connects the data monitoring device as the monitor port.
You can configure the monitor port for a mirroring group in system view, or assign a port to a mirroring
group as the monitor port in interface view. The two modes lead to the same result.
Configuration restrictions and guidelines
When you configure the monitor port for a local mirroring group, follow these restrictions and guidelines:
A mirroring group contains only one monitor port.
Do not enable the spanning tree feature on the monitor port.
HP recommends that you use a monitor port only for port mirroring, so the data monitoring device
receives and analyzes only the mirrored traffic.
Configuration procedure
To configure the monitor port in system view:
Step
1.
Enter system view.
2.
Configure the monitor port for
the specified local mirroring
group.
To configure the monitor port in interface view:
Step
1.
Enter system view.
2.
Enter interface view.
3.
Configure the port as the
monitor port for the specified
local mirroring group.
Command
interface interface-type
interface-number
mirroring-group group-id
mirroring-port { both | inbound |
outbound }
Command
system-view
mirroring-group group-id
monitor-port interface-type
interface-number
Command
system-view
interface interface-type
interface-number
mirroring-group group-id
monitor-port
185
Remarks
N/A
By default, a port does not act as a
source port for any local mirroring
group.
Remarks
N/A
By default, no monitor port is
configured for a local mirroring
group.
Remarks
N/A
N/A
By default, a port does not act as
the monitor port for any local
mirroring group.