3.1
Noise and leakage currents .............................................................................. 42
3.1.1
Leakage currents and countermeasures ................................................................................. 42
3.1.2
Inverter-generated noises and their reduction techniques ...................................................... 44
3.1.3
Power supply harmonics ......................................................................................................... 46
3.1.4
Harmonic suppression guideline ............................................................................................. 47
3.2
Installation of a reactor ..................................................................................... 50
3.3
Power-off and magnetic contactor (MC) .......................................................... 50
3.4
Inverter-driven 400V class motor ..................................................................... 51
3.5
Precautions for use of the inverter .................................................................. 52
4
4.1
Operation panel (FR-DU07) ............................................................................... 56
4.1.1
Parts of the operation panel (FR-DU07) .................................................................................. 56
4.1.2
Basic operation (factory setting) .............................................................................................. 57
4.1.3
Change the parameter setting value ....................................................................................... 58
4.1.4
Setting dial push ...................................................................................................................... 58
4.2
Parameter List .................................................................................................... 59
4.2.1
Parameter list .......................................................................................................................... 59
4.3
Adjust the output torque of the motor (current) ............................................ 70
4.3.1
Manual torque boost (Pr. 0, Pr. 46) ........................................................................................ 70
4.3.2
Simple magnetic flux vector control (Pr.80, Pr.90) ................................................................. 71
4.3.3
Slip compensation (Pr. 245 to Pr. 247)................................................................................... 72
4.3.4
4.4
Limit the output frequency............................................................................... 78
4.4.1
Maximum/minimum frequency (Pr. 1, Pr. 2, Pr. 18) ............................................................... 78
4.4.2
4.5
Set V/F pattern................................................................................................... 80
4.5.1
Base frequency, voltage (Pr. 3, Pr. 19, Pr. 47) ....................................................................... 80
4.5.2
Load pattern selection (Pr. 14) ............................................................................................... 82
4.5.3
Adjustable 5 points V/F (Pr. 71, Pr. 100 to Pr. 109) ............................................................... 83
4.6
Frequency setting by external terminals ........................................................ 84
4.6.1
4.6.2
Jog operation (Pr. 15, Pr. 16) ................................................................................................ 86
4.6.3
Input compensation of multi-speed and remote setting (Pr. 28) ............................................. 88
4.6.4
Remote setting function (Pr. 59) ............................................................................................. 89