Rating - Mitsubishi Electric F700 Instruction Manual

Fr-f720-0.75k to 110k; fr-f740-0.75k to 560k
Hide thumbs Also See for F700:
Table of Contents

Advertisement

Rating

7.1 Rating

•200V class
Type FR-F720-
K
Applicable motor capacity
(kW)
*1
Rated capacity (kVA)
*2
Rated current (A)
*3
Overload current
rating
*4
Voltage
*5
Rated input AC
voltage/frequency
Permissible AC
voltage fluctuation
Permissible frequency
fluctuation
Power
Without DC
supply
reactor
system
With DC
capacity
reactor
(kVA)
*6
Protective structure
(JEM 1030)
*8
Cooling system
Approx. mass (kg)
*1
The applicable motor capacity indicated is the maximum capacity applicable for use of the Mitsubishi 4-pole standard motor.
*2
The rated output capacity indicated assumes that the output voltage is 220V.
*3
When operating the inverter with the carrier frequency set to 3kHz or more, the carrier frequency automatically decreases if the inverter
output current exceeds the value in parenthesis of the rated current. This may cause the motor noise to increase.
*4
The % value of the overload current rating indicated is the ratio of the overload current to the inverter's rated output current. For repeated
duty, allow time for the inverter and motor to return to or below the temperatures under 100% load.
*5
The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changed within the setting
range. However, the pulse voltage value of the inverter output side voltage remains unchanged at about
*6
The power supply capacity varies with the value of the power supply side inverter impedance (including those of the input reactor and
cables).
*7
When the hook of the inverter front cover is cut off for installation of the plug-in option, the inverter changes to an open type ().
*8
FR-DU07: IP40 (except for the PU connector)
266
0.75
1.5
2.2
3.7
5.5
0.75 1.5
2.2
3.7
5.5
1.6
2.7
3.7
5.8
8.8
4.2
7.0
9.6
15.2
23
(3.6)
(6.0)
(8.2)
(13)
(20)
120% for 60s, 150% for 3s (inverse time characteristics)
Three-phase 200 to 220V 50Hz, 200 to 240V 60Hz
2.1
4.0
4.8
8.0
11.5
1.2
2.6
3.3
5.0
8.1
Enclosed type (IP20)
Self-
cooling
1.8
2.2
3.5
3.5
3.5
7.5
11
15
18.5
22
7.5
11
15
18.5
22
11.8 17.1 22.1
27
32
31
45
58
70
85
(26)
(38)
(49)
(60)
(72)
Three-phase 200 to 240V
170 to 242V 50Hz, 170 to 264V 60Hz
±5%
16
20
27
32
41
10
16
19
24
31
*7
Forced air cooling
6.5
6.5
7.8
13
13
30
37
45
55
75
30
37
45
55
75
43
53
65
81
110
114
140
170
212
288
(97)
(119)
(145)
(180)
(245)
52
65
79
99
-
41
50
61
74
110
Open type (IP00)
14
23
35
35
67
that of the power supply.
2
90
110
90
110
132 165
346
432
(294)
(367)
-
-
132
165
70
70