Mitsubishi Electric F700 Instruction Manual page 275

Fr-f720-0.75k to 110k; fr-f740-0.75k to 560k
Hide thumbs Also See for F700:
Table of Contents

Advertisement

•400V class
Type FR-F740-
K
Applicable motor capacity (kW)
Rated capacity (kVA)
*2
Rated current (A)
*3
Overload current rating
*4
Voltage
*5
Rated input AC voltage/frequency
Permissible AC voltage fluctuation
Permissible frequency
fluctuation
Power supply
Without DC reactor
system capacity
With DC reactor
(kVA)
*6
Protective structure
(JEM 1030)
*8
Cooling system
Approx. mass (kg)
Type FR-F740-
K
Applicable motor capacity (kW)
Rated capacity (kVA)
*2
Rated current (A)
*3
Overload current rating
*4
Voltage
*5
Rated input AC voltage/frequency
Permissible AC voltage fluctuation
Permissible frequency fluctuation
Power supply
Without DC reactor
system
LD
With DC
capacity
reactor
SLD
(kVA)
*6
Protective structure
(JEM 1030)
*8
Cooling system
Approx. mass (kg)
*1
The applicable motor capacity indicated is the maximum capacity applicable for use of the Mitsubishi 4-pole standard motor.
*2
The rated output capacity indicated assumes that the output voltage is 440V.
*3
When operating the inverter with the carrier frequency set to 3kHz or more, the carrier frequency automatically decreases if the inverter output
current exceeds the value in parenthesis of the rated current. This may cause the motor noise to increase.
*4
The % value of the overload current rating indicated is the ratio of the overload current to the inverter's rated output current. For repeated duty,
allow time for the inverter and motor to return to or below the temperatures under 100% load.
*5
The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changed within the setting range.
However, the pulse voltage value of the inverter output side voltage remains unchanged at about
*6
The power supply capacity varies with the value of the power supply side inverter impedance (including those of the input reactor and cables).
*7
When the hook of the inverter front cover is cut off for installation of the plug-in option, the inverter changes to an open type (IP00).
*8
FR-DU07: IP40 (except for the PU connector)
0.75
1.5
2.2
3.7
0.75
1.5
2.2
3.7
*1
1.6
2.7
3.7
5.8
2.1
3.5
4.8
7.6
(1.8)
(3.0)
(4.1)
(6.4)
120% 60s, 150% 3s (inverse time characteristics)
2.1
4.0
4.8
8.0
1.2
2.6
3.3
5.0
Self-cooling
3.5
3.5
3.5
3.5
75
90
110 132 160 185 220 250 280 315 355 400 450 500 560
75
90
110
132
*1
110
137
165
198
144
180
216
260
(122)
(153)
(183)
(221)
-
-
-
-
110
137
165
198
137
165
198
247
37
50
57
72
5.5
7.5
11
15
18.5
5.5
7.5
11
15
18.5
8.8
12.2
17.5
22.1
26.7
11.5
16
23
29
(9.8)
(13)
(19)
(24)
Three-phase 380 to 480V
Three-phase 380 to 480V 50Hz/60Hz
323 to 528V 50Hz/60Hz
±5%
11.5
16
20
27
8.1
10
16
19
Enclosed type (IP20)
*7
Forced air cooling
3.5
6.5
6.5
7.5
160
185
220
250
280
247
275
329
366
416
325
361
432
481
547
(276)
(306)
(367)
(408)
(464)
120% 60s, 150% 3s
(inverse time characteristics)
Three-phase 380 to 480V
Three-phase 380 to 480V 50Hz/60Hz
323 to 528V 50Hz/60Hz
±5%
-
-
-
-
-
247
275
329
366
416
275
329
366
416
464
Open type (IP00)
Forced air cooling
72
110
110
175
175
Rating
22
30
37
45
22
30
37
45
32.8
43.4
53.3
64.8 80.8
35
43
57
70
85
(30)
(36)
(48)
(60)
(72)
32
41
52
65
79
24
31
41
50
61
Open type (IP00)
7.5
13
13
23
35
315
355
400
450
500
464
520
586
659
733
610
683
770
866
962
(518)
(580)
(654)
(736)
(817)
-
-
-
-
-
464
520
586
659
733
520
586
659
733
833
175
260
260
370
370
that of the power supply.
2
55
55
106
(90)
99
74
35
560
833
1094
(929)
-
833
923
370
7
267