Mitsubishi Electric F700 Instruction Manual page 206

Fr-f720-0.75k to 110k; fr-f740-0.75k to 560k
Hide thumbs Also See for F700:
Table of Contents

Advertisement

Communication operation and setting
Parameter
Parameters Register
41000 to
0 to 999
C2(902)
C3(902)
125(903)
C4(903)
C5(904)
C6(904)
126(905)
C7(905)
Alarm history
Register
40501
Alarm history 1
40502
Alarm history 2
40503
Alarm history 3
40504
Alarm history 4
40505
Alarm history 5
40506
Alarm history 6
40507
Alarm history 7
40508
Alarm history 8
Data
Description
H00
No alarm
H10
OC1
H11
OC2
H12
OC3
H20
OV1
H21
OV2
H22
OV3
H30
THT
H31
THM
H40
FIN
H50
IPF
H51
UVT
198
Parameter Name
Refer to the parameter list (page
41999
59) for the parameter names.
Terminal 2 frequency setting
41902
bias (frequency)
Terminal 2 frequency setting
42092
bias (analog value)
Terminal 2 frequency setting
43902
bias (terminal analog value)
Terminal 2 frequency setting
41903
gain (frequency)
Terminal 2 frequency setting
42093
gain (analog value)
Terminal 2 frequency setting
43903
gain (terminal analog value)
Terminal 4 frequency setting
41904
bias (frequency)
Terminal 4 frequency setting
42094
bias (analog value)
Terminal 4 frequency setting
43904
bias (terminal analog value)
Terminal 4 frequency setting
41905
gain (frequency)
Terminal 4 frequency setting
42095
gain (analog value)
Terminal 4 frequency setting
43905
gain (terminal analog value)
Definition
Alarm code list
Data
Description
H52
ILF
H60
OLT
H70
BE
H80
GF
H81
LF
H90
OHT
H91
PTC
HA0
OPT
HA1
OP1
HB0
PE
HB1
PUE
HB2
RET
Read/Write
Read/write
Read/write
Read/write
Read
Read/write
Read/write
Read
Read/write
Read/write
Read
Read/write
Read/write
Read
Read/Write
Read/write
Read
Being 2 bytes in length, the data is stored as
Read
"H00
Read
the low-order 1 byte.
Read
Performing write using the register 40501 batch-
Read
clears the alarm history. Set any value as data.
Read
Read
Data
Description
HB3
PE2
HC0
CPU
HC1
CTE
HC2
P24
HC4
CDO
HC5
IOH
HC6
SER
HC7
AIE
HF1
E.1
HF6
E.6
HF7
E.7
HFD
E.13
Remarks
The parameter number + 41000 is the
register number.
The analog value (%) set to C3 (902) is
read.
The analog value (%) of the voltage (current)
applied to the terminal 2 is read.
The analog value (%) set to C4 (903) is
read.
The analog value (%) of the voltage
(current) applied to the terminal 2 is read.
The analog value (%) set to C6 (904) is
read.
The analog value (%) of the current (voltage)
applied to the terminal 4 is read.
The analog value (%) set to C7 (905) is
read.
The analog value (%) of the current (voltage)
applied to the terminal 4 is read.
Remarks
". The error code can be referrred to in