Communication operation and setting
No.
Item
Alarm definition all
7
clear
8
All parameter clear
9
Parameters
10
Link parameter
11
extended setting
Second parameter
changing
12
(instruction code
HFF=1)
Refer to page 180 for data formats (A, A', B, B', C, D)
REMARKS
⋅ Set 65520 (HFFF0) as a parameter value "8888" and 65535 (HFFFF) as "9999".
⋅ For the instruction codes HFF, HEC and HF3, their values are held once written but cleared to zero when an inverter reset or all
clear is performed.
Example) When reading the C3 (Pr. 902) and C6 (Pr. 904) settings from the inverter of station No. 0
Computer Send Data
1)
ENQ 00 FF 0 01 82
2)
ENQ 00 EC 0 01 7E
3)
ENQ 00 5E 0 0F
4)
ENQ 00 60 0 FB
To read/write C3 (Pr. 902) and C6 (Pr. 904) after inverter reset or parameter clear, execute from 1) again.
186
Read
Instruction
/write
Code
Write
HF4
H9696: Alarm history batch clear
All parameters return to the initial values.
Any of four different all clear operations are performed
according to the data.
Data
H9696
H9966
H5A5A
Write
HFC
H55AA
When all parameter clear is executed for H9696 or H9966,
communication-related parameter settings also return to the
initial values. When resuming operation, set the parameters
again.
*1
Refer to page 177, 178.
*2
Refer to the list of calibration parameters on the next page for
calibration parameters.
*3
Pr. 75 is not cleared
H00 to
Refer to the instruction code (page 288) and write and/or read
Read
H63
the values as required.
When setting
H80 to
Write
must be set.
HE3
Parameter description is changed according to the H00 to H09
Read
H7F
setting.
For details of the setting, refer to the instruction code (page
Write
HFF
288).
When setting the calibration parameters
H00:Frequency
Read
H6C
H01: Parameter-set analog value
H02: Analog value input from terminal
*1
Refer to the list of calibration parameters on the next page for
calibration parameters.
Write
HEC
*2
The gain frequency can also be written using Pr. 125 (instruction
code H99) or Pr. 126 (instruction code H9A).
Inverter Send Data
ACK 00
Set "H01" in the extended link parameter.
ACK 00
Set "H01" in second parameter changing.
STX 00 0000 ETX 25
C3 (Pr. 902) is read. 0% is read.
STX 00 0000 ETX 25
C6 (Pr. 904) is read. 0% is read.
Data Description
Pr.
Communi-
Calibration
cation Pr.
Pr.
*2
*1
×
×
×
×
and later, link parameter expansion setting
Pr.100
*2
Description
Data Digits
HEC
Other Pr.
HF3
*3
HFF
*1
Number of
(format)
4 digits
(A,C/D)
4 digits
(A,C/D)
4 digits
(B.E/D)
4 digits
(A,C/D)
2digits
(B.E'/D)
2digits
(A',C/D)
2digits
(B.E'/D)
2digits
(A',C/D)

Hide quick links: