Mitsubishi Electric F700 Instruction Manual page 116

Fr-f720-0.75k to 110k; fr-f740-0.75k to 560k
Hide thumbs Also See for F700:
Table of Contents

Advertisement

Function assignment of external
terminal and control
Setting
Signal
Positive
Negative
Name
Logic
Logic
14
114
FDN
15
115
FUP
16
116
RL
17
MC1
18
MC2
19
MC3
25
125
FAN
26
126
FIN
45
145
RUN3
46
146
Y46
47
147
PID
64
164
Y64
70
170
SLEEP
90
190
Y90
91
191
Y91
92
192
Y92
93
193
Y93
94
194
ALM2
95
195
Y95
96
196
REM
98
198
LF
99
199
ALM
9999
*1
Note that when the frequency setting is varied using an analog signal or
frequency) signal may alternate on and off depending on that varying speed and the timing of the varying speed due to acceleration/
deceleration time setting. (The output will not alternate on and off when the acceleration/deceleration time setting is "0s".)
*2
When a power supply reset is performed, the alarm output 2 signal (ALM2) turns off as soon as the power supply switches off.
108
Function
Output when the feedback value falls below
PID lower limit
the lower limit of PID control.
Output when the feedback value rises above
PID upper limit
the upper limit of PID control
PID forward/reverse
Output when forward rotation is performed in
rotation output
PID control.
Commercial power-
supply switchover MC1
Commercial power-
Used when the commercial power supply-
supply switchover MC2
inverter switchover function is used.
Commercial power-
supply switchover MC3
Fan fault output
Output at the time of a fan fault.
Output when the heatsink temperature
Heatsink overheat
reaches about 85% of the heatsink overheat
pre-alarm
protection providing temperature.
During inverter
Output when the inverter running and start
running and start
commands are on.
command is on
During deceleration at
occurrence of power
Output when the power failure-time
failure (retained until
deceleration function is executed.
release)
During PID control
Output during PID control.
activated
During retry
Output during retry processing.
PID output
Output when the PID output interruption
interruption
function is executed.
Output when any of the control circuit
capacitor, main circuit capacitor and inrush
Life alarm
current limit circuit or the cooling fan
approaches the end of its service life.
Alarm output 3
Output when an error occurs due to the circuit
(power-off signal)
failure or connection alarm of the inverter.
Turned on and off alternately every time the
Power saving
power saving average value is updated
average value
when the power saving monitor is used.
updated timing
Cannot be set to Pr. 195 and Pr. 196 (relay
output terminal).
Average current value and maintenance
Current average
timer value are output as pulses.
value monitor signal
Cannot be set to Pr. 195 and Pr. 196 (relay
output terminal).
Output when the inverter's protective
function is activated to stop the output
Alarm output 2
(major fault). Continue outputting the signal
during inverter reset and stop outputting
after reset is cancelled.
Maintenance timer
Output when Pr. 503 rises to or above the Pr.
signal
504 setting.
Output to the terminal when a value is set to
Remote output
the parameter.
Output when a minor fault (fan failure or
Minor fault output
communication error warning) occurs.
Output when the inverter's protective function is
Alarm output
activated to stop the output (major fault). The
signal output is stopped when a reset turns on.
No function
Operation
*2
of the operation panel (FR-DU07), the output of the SU (up to
Related
Refer
Parameters
to Page
Pr. 127 to Pr. 134,
201
Pr. 575 to Pr. 577
Pr. 135 to Pr. 139,
209
Pr. 159
Pr. 244
216
242
109
Pr. 261 to Pr. 266
130
Pr. 127 to Pr. 134,
201
Pr. 575 to Pr. 577
Pr. 65 to Pr. 69
132
Pr. 127 to Pr. 134,
201
Pr. 575 to Pr. 577
Pr. 255 to Pr. 259
217
110
Pr. 52, Pr. 54,
Pr. 158, Pr. 891 to
137
Pr. 899
Pr. 555 to Pr. 557
220
109
Pr. 503, Pr. 504
219
Pr. 495 to Pr. 497
114
177,
Pr. 121, Pr. 244
216
109