Function Parameters
57
Restart coasting time
58
Restart cushion time
59
Remote function selection
60
Energy saving control selection
65
Retry selection
Stall prevention operation reduction
66
starting frequency
67
Number of retries at alarm occurrence 0 to 10, 101 to 110
68
Retry waiting time
69
Retry count display erase
70
Special regenerative brake duty
71
Applied motor
72
PWM frequency selection
73
Analog input selection
74
Input filter time constant
Reset selection/disconnected PU
75
detection/PU stop selection
76
Alarm code output selection
77
Parameter write selection
78
Reverse rotation prevention selection
79
Operation mode selection
Motor capacity(simple magnetic flux
80
vector control)
90
Motor constant (R1)
100
V/F1(first frequency)
101
V/F1(first frequency voltage)
102
V/F2(second frequency)
103
V/F2(second frequency voltage)
104
V/F3(third frequency)
105
V/F3(third frequency voltage)
106
V/F4(fourth frequency)
107
V/F4(fourth frequency voltage)
108
V/F5(fifth frequency)
109
V/F5(fifth frequency voltage)
117
PU communication station number
118
PU communication speed
119
PU communication stop bit length
120
PU communication parity check
121
Number of PU communication retries
PU communication check time
122
interval
PU communication waiting time
123
setting
PU communication CR/LF presence/
124
absence selection
Name
0, 0.1 to 5s, 9999/
0, 0.1 to 30s, 9999
0 to 60s
0, 1, 2, 3
0, 4, 9
0 to 5
0 to 400Hz
0 to 10s
0
0 to 10%
0, 1, 2, 20
0 to 15/0 to 6, 25
0 to 7, 10 to 17
0 to 8
0 to 3, 14 to 17
0, 1, 2
0, 1, 2
0, 1, 2
0, 1, 2, 3, 4, 6, 7
0.4 to 55kW, 9999/
0 to 3600kW, 9999
0 to 50Ω, 9999/
0 to 400mΩ, 9999
0 to 400Hz, 9999
0 to 1000V
0 to 400Hz, 9999
0 to 1000V
0 to 400Hz, 9999
0 to 1000V
0 to 400Hz, 9999
0 to 1000V
0 to 400Hz, 9999
0 to 1000V
0 to 31
48, 96, 192, 384
0, 1, 10, 11
0, 1, 2
0 to 10, 9999
0, 0.1 to 999.8s, 9999
0 to 150ms, 9999
0, 1, 2
Minimum
Setting Range
Setting
Increments
0.1s
0.1s
1
1
1
0.01Hz
1
0.1s
1
0.1%
1
1
1
1
1
1
1
1
1
0.01/0.1kW
0.001Ω/
0.01mΩ
0.01Hz
0.1V
0.01Hz
0.1V
0.01Hz
0.1V
0.01Hz
0.1V
0.01Hz
0.1V
1
1
1
1
1
0.1s
1
1
Parameter List
Refer
Initial
Customer
to
Value
Setting
Page
9999
126
1s
126
0
89
0
136
0
132
60Hz
73
0
132
1s
132
0
132
0%
99
0
97
2
142
1
146
1
147
14
153
0
134
0
155
0
156
0
158
9999
71
9999
71
9999
83
0V
83
9999
83
0V
83
9999
83
0V
83
9999
83
0V
83
9999
83
0V
83
0
177
192
177
1
177
2
177
1
177
9999
177
9999
177
1
177
61
4