Figure 17 Release the Rack Latches
3.
Slide the server out of the rack until the guide-rail release clips are visible.

Inserting the Server into the Rack

To insert the server into the rack, perform the following step:
1.
Press the rail clips on either side of the server inward and push the server into
the rack until it stops.
2.
Verify that the rack latches are closed.

Removing and Replacing the Top Metal Cover

The following procedures describe how to remove and replace the top metal cover.

Removing the Top Metal Cover

1.
Power off the server and disconnect the power cable and all other cables from
the back of the server.
CAUTION:
within 30 minutes to prevent components from overheating. If the top metal cover
is not replaced within 30 minutes, the server automatically shuts down.
If the server shuts down, replace the top metal cover before you restart the server.
2.
Ensure the top metal cover lock keyswitch is in the unlocked position. Rotate the
blue release lever toward the back of the server and slide the cover toward the
back of the server. See
When the server is running, you must replace the top metal cover
Figure
18.
33