Removing and Replacing Components

Accessing a Pedestal-Mounted Server

Step 2. Flip out the two pull handles at either end of the front bezel and slowly pull the unit forward by the
handles. The server is fully extended when the rail clips are locked in place. When fully extended,
the front and top covers are fully accessible.

Inserting the Server Into the Rack

To insert the server into the rack, follow these steps:
Step 1. Press the rail clips on either side of the server inward and push the server into the rack until it
stops.
Step 2. Replace the T-25 screws that fasten the server to the rack.

Accessing a Pedestal-Mounted Server

The HP 9000 rp4410 and rp4440 servers are also designed for use in a stand-alone pedestal (rackless)
environment. A pedestal is available for use with the server in a floor- or pedestal-mount configuration.
You do not need to remove the pedestal from the server to gain access to internal components.
The front bezel, front cover, and top cover can be removed with the pedestal attached to the server.
178