Powering Off The Server Manually; Powering On The Server; Powering On The Server Using Ilo; Powering On The Server Manually - HP Integrity rx2620 User's & Service Manual

Hide thumbs Also See for Integrity rx2620:
Table of Contents

Advertisement

Powering Off the Server Manually

To manually power off the server through iLO:
1.
Gracefully shut down the operating system. See
operating system documentation.
2.
Press the Power button to power off the server.
IMPORTANT:
AC voltage for standby power is still present in the server.
3.
Unplug all power cables from the receptacles on the rear panel of the server.

Powering On the Server

Power on the server to full power using the following methods if the server is in the
standby power state:
iLO MP PC command
Power button

Powering On the Server Using iLO

NOTE:
If the power restore feature is set to Always On through the iLO MP PR
command, the server might automatically power on to the full power state.
To power on the server through iLO:
1.
Plug all power cables into the receptacles on the rear panel of the server.
2.
Initiate a console session, and access the iLO MP Main Menu.
3.
Enter CM to enable command mode.
4.
Enter PC to use the remote power control command.
5.
Enter ON to power on the server, and enter YES when prompted to confirm the
action.
6.
Start the operating system. See
documentation.

Powering On the Server Manually

NOTE:
If the power restore feature is set to Always On through the iLO MP PR
command, the server might automatically power on to the full power state.
To manually power on the server:
1.
Plug all power cables into the receptacles on the rear panel of the server.
2.
Press the Power button to start the server.
3.
Start the operating system. See
documentation.
The main DC voltage is now removed from the server; however,
Appendix B (page
Appendix B (page
Appendix B (page
116), or your
116), or your operating system
116), or your operating system
28

Advertisement

Table of Contents
loading

Table of Contents