Extending The Server From The Rack; Inserting The Server Into The Rack; Figure 4-1 Accessing 25Mm Torx Screws - HP Integrity rx4640 User's & Service Manual

Hide thumbs Also See for Integrity rx4640:
Table of Contents

Advertisement

Extending the Server from the Rack

Ensure that there is enough area (Approximately 1.5 meters [4.5 ft.]) to fully extend the server
NOTE
out the front and work on it.
To extend the server from the rack, follow these steps:
Step 1. Remove the T-25 screws that fasten the server to the rack. See Figure 4-1, "Accessing 25MM Torx
Screws."
Step 2. Flip out the two pull handles at either end of the front bezel and slowly pull the unit forward by the
handles. The server is fully extended when the rail clips are locked in place. When fully extended,
the front and top covers are fully accessible.
Figure 4-1
Accessing 25MM Torx Screws

Inserting the Server into the Rack

To insert the server into the rack, follow these steps:
Step 1. Press the rail clips on either side of the server inward and push the server into the rack until it
stops.
Step 2. Replace the T-25 screws that fasten the server to the rack.
Chapter 4
Removing and Replacing Components
Accessing a Rack Mounted Server
25MM Torx
screw 2X
39