External Core I/O

One SCSI U320 68 pin connector
Two 10/100/1000Base-T Ethernet LAN connectors for twisted-pair cable
Four USB 2.0 ports
Two general purpose or 9-pin serial ports, 16550 compatible

Power Supply Unit

600 W output power
Front-end block (the actual power supply case) that converts the line voltage into
a high DC voltage.
Back-end voltage regulation modules (on the system board) that step down the
front-end DC voltage to the required voltages
Redundant and hot-pluggable power supplies (front-end block only)

System Board Manageability

Baseboard Management Controller (BMC)
Temperature monitoring and fans regulation by BMC
BMC manageability console shared with server console and general purpose
serial port
IPMI protocol for communication between BMC/server/MP hardware
BMC hardware diagnostics display on the front status panel
E-buzzer remote hardware diagnostics on phone lines for support
Locator front/rear LEDs
Field replacement units monitoring by BMC
Serial port for local and modem console
Wake-on-LAN and Alert-on-LAN capabilities from the 10/100/1000 BT LAN port
Enhanced Server Manageability Using the Integrated Lights Out
Management Processor
The integrated Lights Out Management Processor (iLO MP) provides the following
enhancements to server manageability:
Web-based graphical user interface (GUI)
LAN telnet console
Web console
Serial port for local console
Serial port for modem console
Duplication of console screen content across all consoles
VGA and 2 D graphics display
Advanced Features:
Secure Shell (SSH) access