8-4
STATUS lamp
Description
indication
Flashing green
The server is in operation with its
processor degraded.
The server is in operation with its
memory degraded.
A correctable memory or bus
error was detected.
Unlit
The server is powered off.
POST is in progress.
A processor error occurred
(IERR).
A processor thermal error was
detected. (Thermal-Trip)
A watchdog timer has timed out.
A PCI system error occurred.
A PCI parity error occurred.
An uncorrectable memory error
was detected.
An uncorrectable bus error was
detected.
POST terminates with error.
Memory dumping is requested.
Lit amber
A thermal error (critical) was
detected.
A voltage error (critical) was
detected.
A power supply(ies) failed to
operate.
Flashing
A power alarm was detected in a
amber
power supply unit.
A fan alarm was detected.
A thermal error (warning) was
detected.
A voltage error (warning) was
detected.
Action
Contact your service representative.
Start the BIOS SETUP and select [Main] - [Processor
Settings] to identify the degraded processor and replace it
as soon as possible.
Or, start the BIOS SETUP and select [Main] - [Processor
Settings] - [Processor Retest] - [Yes], and then select [Exit] -
[Exit Saving Changes] to solve the problem.
Contact your service representative.
Start the BIOS SETUP and select [Advanced] - [Memory
Configuration] to identify the degraded memory (DIMM) and
replace it as soon as possible.
Or, start the BIOS SETUP and select [Advanced] - [Memory
Configuration] - [Memory Retest] - [Yes], and then select
[Exit] - [Exit Saving Changes] to solve the problem.
The system can continue operation if the status lamp
flashes green. However, consult with your service
representative.
Power on the server.
Wait for a while. The STATUS lamp will light in a few
seconds after POST completion.
Cycle power to the server. If POST displays an error
message, take a note on the message and contact your
service representative.
Wait until memory dumping completes.
Check internal fans for dust or debris. Also make sure that
the fans are firmly connected.
If this error indication persists, contact your service
representative.
Contact your service representative.
Contact your service representative.
Identify the failed power supply unit and contact your
service representative.
Make sure that the fan units are firmly connected.
If this error indication persists, contact your service
representative.
Check internal fans for dust or debris. Also make sure that
the fan units are firmly connected.
If this error indication persists, contact your service
representative.