F-Code Transmission And Polling - Muratec MFX-1500 Operating Instructions Manual

Plain-paper fax machine
Hide thumbs Also See for MFX-1500:
Table of Contents

Advertisement

Beyond the bas cs
6
Use the numeric keypad to enter your F-Code's four-digit passcode. Here
we've entered 2345:
03:Print F-Code Doc.
F-Code Passcode:2345
7
Press
.
ENTER
If you've entered the correct passcode, your fax machine will print all
documents in — and then erase them from — the mailbox.
If you've entered an incorrect passcode, your fax machine will refuse to
print the document.

F-Code transmission and polling

With F-Code, your machine — in addition to sending Muratec-proprietary
SecureMail (pages 2.38–2.41) and performing database polling (pages 2.31–2.32)
from only other Muratec models — can send secure transmissions to, and perform
database polling from, other makers' machines, as well. You may accomplish such
transmissions in either of two ways:
Programmable one-touch key (see pages 2.67–2.69)
Direct entry of the
-
subaddress and password, which is what we will
ITU
T
now describe.
Whether you are sending to or polling from another machine, you obviously must
know the correct sub-address on the receiving machine, as well as the password if
that sub-address has one. (This is analogous to how, with Muratec SecureMail, you
must know the correct SecureMail mailbox number and password on the remote
Muratec fax.)
Note: For F-Code communication to occur, three things must be true:
The remote fax machine must support
password) capabilities.
A mailbox with an
-
sub-address must exist on the remote fax. (It
ITU
T
doesn't have to have a password. If the other machine hasn't at least one
box with a sub-address, F-Code communication will be impossible.)
You must know the
-
sub-address and (if applicable) password
ITU
T
information for the mailbox on the remote machine.
F-Code transmission
1.
Press
/
to change to Fax mode, if necessary.
COPY
FAX
2.
Insert the document.
3.
Adjust resolution and contrast if necessary.
2.58
-
sub-addressing (and
ITU
T
4.
If you wish to toggle between transmission from the feeder and
transmission from memory, press
Note: This toggle affects only a transmission from the
from the
is always memory transmission.
FBS
5.
Press
COMMUNICATION OPTIONS
7.F-Code TX
Comm.Option/Enter
6.
Press
.
ENTER
Enter Sub-Address
_
7.
Use the numeric keypad to enter the appropriate sub-address number. In
this example, we've entered 123456.
Enter Sub-Address
123456_
Note: If you make a mistake, press
correct one-digit number.
8.
Press
. The display will show:
ENTER
Enter Password
_
Note: If you know that this sub-address does not have a password, skip
to step 10.
9.
Use the numeric keypad to enter the appropriate password number. In this
example, we've entered 654321.
Enter Password
654321_
Note: If you make a mistake, press
correct one-digit number.
10.
Press
. The display will show:
ENTER
Enter Fax Number
_
11.
Enter the fax number either by pressing a one-touch key, entering a speed-
dial number or dialing from the numeric keypad. Do not press
12.
What you do now depends upon when you wish the transmission to begin.
To have it begin now, skip to step 15.
To delay it, proceed to step 13.
.
MEMORY TRANSMIT
. Transmission
ADF
seven times and then press
.
ENTER
to back up, then enter the
CANCEL
to back up, then enter the
CANCEL
.
START

Advertisement

Table of Contents
loading

Table of Contents