Cooling system and lubrication system
Insert the cover of the thermostat, complete with ther-
mostat onto the engine.
10 N•m
Tighten the three fixing screws (1) to the prescribed
torque pressure.
Torque pressure: 10 N•m
1
If the water temperature sensor connector was remo-
ved previously, the following action must be taken.
Tighten the H
O sensor (1) for gearcase, ensuring that
2
the connector is in horizontal or standing position.
1
L
For Brutale 750 ORO-S / Brutale 910 S-R MY 05/06
models only:
Connect the connector (1) to the sensor.
1