Programming

Panel IR Commands

These commands are used to transmit and receive IR signals from the panel.
Each panel has up to 4 transmit ports specifically defined as IR output ports:




The ^IRM command allows the command itself to specify the port number. IRM is needed because commands
programmed on the panel itself can only be sent to a single port number.
The ^IRS command is needed to enable the received AMX 38K or 455k. In some cases, both of these ports cannot be
enabled at the same time.
Panel IR Commands

^IRM

^IRS

112
AMX 38K
AMX 455K
User 1
User 2
Pulses the given channel IR on for onTime in tenths of seconds.
Delays offTime tenths of seconds before the next IR pulse is allowed.
The port for the IR is specified in the command.
Syntax:
SEND_COMMAND <DEV>,"'^IRM-<port>,<channel>,<onTime>,<offTime>'"
Variables:
None.
Example:
SEND_COMMAND TP1,"'^IRM-<port>,<channel>,<onTime>,<offTime>'"
SEND_COMMAND TP2,"'^IRM-<port>,<channel>,<onTime>,<offTime>'"
Specifies the port number to be used.
Enable the received AMX 38K or 455K
The RX Ir port is specified in the command.
Syntax:
SEND_COMMAND <DEV>,"'^IRS-<port>'"
Variables:
None.
Example:
SEND_COMMAND <DEV>,"'^IRS-<port>'"