Programming

^RAF, ^RMF - Embedded Codes

The ^RAF and ^RMF commands add and modify any and all resource parameters by sending embedded codes and data:
"'^RAF-<resource name>,<data>'"
"'^RMF-<resource name>,<data>'"
The <data> variable uses the embedded codes described in the following table:
^RAF, ^RMF - Embedded Codes
Parameter
protocol
user
password
host
file
path
refresh
newest
preserve
108
Embedded Code
'%P <0-1>'
'%U <user>'
'%S <password>'
'%H <host>'
'%F <file>'
'%A <path>'
'%R <refresh 1-65535>'
'%N <0-1>'
'%V <0-1>'
Description
Set protocol. HTTP (0) or FTP (1).
Set Username for authentication.
Set Password for authentication.
Set Host Name (fully qualified DNS or IP Address).
Full path to the location of the file or program that will return the resource.
The path must be a valid HTTP URL minus the protocol and host.
The only exception to this is the inclusion of special escape sequences
and in the case of FTP protocol, regular expressions.
Set Directory path. The path must be a valid HTTP URL minus the
protocol, host and filename.
The only exception to this is the inclusion of special escape sequences
and in the case of FTP protocol, regular expressions.
The number of seconds between refreshes in which the resource is
downloaded again. Refreshing a resource causes the button displaying
that resource to refresh also.
The default value is 0 (only download the resource once).
Set the newest file. A value of 1 means that only the most recent file
matching the pattern is downloaded.
The 'newest file' option only applies to FTP Dynamic Images, and only
those that have pattern matching as part of their filename.
Neither 'newest file' nor pattern matching apply to HTTP Dynamic
Images.
When set, the panel will first pull a list of files matching the given pattern
from the specified FTP server and path. The timestamps of the items in
the list will be compared, with the newest one being displayed on the
panel. This is useful for source devices that place a uniquely named still
image in a folder at constant intervals, allowing the panel always to
display the most recent one.
Set the value of the preserve flag.
Default is 0. Currently preserve has no function.