AMX NXD-500i Operation/Reference Manual page 66

5" modero wall/flush mount touch panel with intercom
Hide thumbs Also See for NXD-500i:
Table of Contents

Advertisement

Setup Pages and Descriptions
G4 Web Control Settings Page
Back:
Wired icon:
Connection Status icon:
G4 Web Control Settings:
Enable/Enabled:
Network Interface
Select:
Web Control Name:
Web Control Password: Allows entry of the G4 Authentication session password associated for VNC web access of
Web Control Port:
Maximum Number of
Connections:
Current Connection
Count:
G4 Web Control Timeout:
FIG. 53
Sample relationship between G4 Web Control and Manage WebControl Connections window
Refer to the Using G4 Web Control to Interact with a G4 Panel section on page 32 for more detailed instructions on how
to use the G4 Web Control page with the new web-based NetLinx Security application.
54
Saves the changes and returns to the previously active touch panel page.
The icon to the left of the Connection Status Icon displays that the current connection to the
Master is Wired (image of three networked computers).
This visual display of the connection status allows the user to have a current visual update
of the panel's connection status regardless of what page is currently active.
A Lock only appears on the icon if the panel has established a connection with a currently
secured target Master (requiring a username and password).
Sets the IP communication values for the touch panel and contains:
The Enable/Enabled button allows you to toggle between the two G4 activation settings:
• Enable - deactivates the G4 Web Control feature on the panel.
• Enabled - activates the G4 Web Control feature on the panel and allows an external PC
running a VNC client to access the panel after the remaining fields are configured.
Displays the detected method of communication to the web:
• Wired is used when a direct Ethernet connection is being used for communication to the
web. This is a default setting.
Allows entry of a unique alphanumeric string used as the display name of the panel within
the Manage WebControl Connections window of the new NetLinx Security browser window.
This Web Control tab displays a G4 icon alongside the link to the Web Control Name given
to this panel (FIG. 53).
this panel.
Allows entry of the VNC Web Server's port value.
• Default value is 5900.
This read-only field displays the maximum number of users that can be simultaneously
connected to the target panel via the Web.
• Default value is 1.
This read-only field displays the current number of users connected to the target panel via
the Web. This value cannot exceed the Maximum number field.
Sets the length of time (in minutes) the panel can remain idle (no cursor
movements) before the session is closed and the user is disconnected.
• Minimum value = 0 minutes (panel never times-out)
• Maximum value = 240 minutes (panel times-out after 240 minutes/4hours)
NXD-500i 5" Modero Wall/Flush Mount Touch Panel with Intercom