T190 - Dell PowerVault ML6000 Maintenance Manual

Tape library
Hide thumbs Also See for PowerVault ML6000:
Table of Contents

Advertisement

T190

T190 - Library Configuration Corruption
Description
Detection Scenarios
Root Causes
Service Resolution
Steps
Possible CRUs/FRUs
PowerVault ML6000 Maintenance Guide
GUI Description: The library detected a configuration file corruption, and
reset some configuration parameters to factory defaults.
Explanation: The library detected a missing or corrupted configuration file,
which required the library control firmware to recreate a configuration file with
factory default settings. This issue could cause various side effects, such as
drives not having the proper SCSI ID or having conflicting SCSI ID settings, or
more problematically, having a drive that previously encrypted its data no
longer encrypt data on tape. This ticket provides an alert of such problems, as
the library is not always able to properly reconstruct configuration settings or
prevent drives from initializing incorrectly.
• The library did not locate a required configuration file.
• The library detected a corrupted configuration file.
The library encountered an exception condition that resulted in a "core" and
restart of the system.
Perform
DR146 - Resolve Drive Tape Alert 54 - No Start of Data
None
on page 419.
361