T120 - Dell PowerVault ML6000 Maintenance Manual

Tape library
Hide thumbs Also See for PowerVault ML6000:
Table of Contents

Advertisement

T120

T120 - Robotics Y-Axis Motion Failure, Tape In Picker
Description
Detection Scenarios
Root Causes
Service Resolution
Steps
Possible CRUs/FRUs
PowerVault ML6000 Maintenance Guide
This ticket applies to Model 2 robots only.
GUI Description: A Y-axis motion error occurred while the robot was moving
a tape cartridge.
Explanation: A Y-axis motion error that cannot be considered a complete
obstruction has been reported by robotics. Because a tape cartridge is in the
picker, tape cartridge recovery must be a part of the resolution strategy. This
RAS ticket only occurs during a robotics move, not during a robotics get or
put.
• A specified move in the y-axis cannot complete.
• Robotics firmware reports a y-axis error condition.
• A physical obstruction in the path of the robot's motion. Examples include
tape cartridges that are extending from the picker assembly or from a
storage location, as well as tape cartridges or debris that may have collected
on the floor of the library.
• A large number of electrical hardware failures. Firmware or hardware
detects that motion control is not occurring properly (encoder issues, motor
driving circuits, motor winding issues, etc.).
• A relatively small number of mechanical hardware failures that do not result
in the detection of a complete obstruction, but where motion control
generates robotics firmware error codes (contamination or damage to
encoder wheel, high friction, etc.).
Perform
DR088 - Resolve Robotics Y-Axis Motion Failure
Note: Read and perform all resolution steps before dispatching any parts.
Dispatch the first part listed below for replacement. If this does not solve the
problem, dispatch the second part, and so on, in order. Dispatch only one part
(or set of parts) at a time.
1 Robot Assembly
2 Cable Spool
on page 405.
319

Advertisement

Table of Contents
loading