T047

T047 - Drive TapeAlert 22 - Expired Cleaning Media
Description
Detection Scenarios
Root Causes
Service Resolution
Steps
Possible CRUs/FRUs
244
GUI Description: The cleaning tape cartridge has been used up and can no
longer clean a tape drive.
Explanation: System determines that a cleaning media is expired.
Tape drive issues a TapeAlert 22.
The cleaning media within the cartridge is used up (expired).
1 Perform
RR008 - Remove and Replace Tape Cartridge
the Dell PowerVault ML6000 Tape Library User's Guide for information on
removing and replacing a cartridge.
2 Use the Details option in the RAS ticket to identify which tape drive contains
the expired cleaning media which reported the RAS ticket.
3 Clear the RAS ticket.
4 Unload and export the cleaning media from the library.
5 Load a known good cleaning tape and either manually move it to the tape
drive or perform a cleaning operation in the tape backup software.
No library CRU or FRU is involved. Rather, this is an indication that the
cleaning tape media is expired and needs to be replaced.